กระจกตาแมว แบบมีแถบแสดงตรวจจับความชื้น 1/4" ODS Solder. (เชื่อมบัคกรี) Product Details Connections Ø ODS [in.] 1/4" PS [bar] 50 MWP [psi] (1) 500 TS [°C] min. -40 mTS [°C] max. +120"

Brand : Castel
Model : 3940/2
Product type : Castel Sight glass solder
Size : inlet x outlet =1/4" ODS X 1/4" ODS solder.
Details : กระจกตาแมว แบบมีแถบแสดงตรวจจับความชื้นMoisture Indicator
1/4"ODS Solder. (เชื่อมบัคกรี) use with the following ASHRAE 34:2019 refrigerants, Class A1:
HCFC (R22) HFC (R134a, R404A, R407C, R410A, R507)
HFO (R1234ze) HFO + HFC (R448A, R449A, R450A, R452A, R513A, R515A, R515B)
Product Details Connections Ø ODS [in.] 1/4" PS [bar] 50 MWP [psi] (1)
500 TS [°C] min. -40 TS [°C] max. +120
กระจกตาแมว แบบมีแถบแสดงตรวจจับความชื้น 3/4"ODS Solder. (เชื่อมบัคกรี) Product Details Connections Ø ODS [in.] 3/4" PS [bar] 50 MWP [psi] (1) 500 TS [°C] min. -40 TS [°C] max. +120
Stop valves by diaphragm Diaphragm Valve 3/4"O DS Product use with the following ASHRAE 34:2019 refrigerants, Class A1: HCFC (R22) HFC (R134a, R404A, R407C, R410A, R507) HFO (R1234ze)
กระจกตาแมว แบบมีแถบแสดงตรวจจับความชื้น 1/4" SAE.Flare. (ขันเกลียว) Product Details Connections Ø SAE.Flare [in.] 1/4" PS [bar] 50 MWP [psi] (1) 500 TS [°C] min. -40 TS [°C] max. +120"
Safety devices 1/2" NP x 5/8" SAE Model 3060/45(29)
Flang shut off Valve, Outlet Flare Jointed 5/8" SAE. with in Access Valve Flare 1/4" SAE.
Check Valve inlet -outlet Connecting =1/2" Male SAE Flare. made from hot pressed brass with Teflon (PTFE) valve seat Stainless steel spring"
Solenoid valve G.1/2" FPT Direct, only used with Light Oil,water,gas, MOPD.=0 to 10 bar ,Kv=0.40m3/h ,Ps30 bar ,Ts= -15 to +130 C
RECEIVER VALVES inlet Connecting = 1/4" Male NPT. - outlet Connecting = 1/4" Male SAE.FLARE made from hot pressed brass with Teflon (PTFE) valve seat"
Stop valves by diaphragm Diaphragm Valve 1/2"Flare inlet and outlet. Valve use with the following ASHRAE 34:2019 refrigerants, Class A1: HCFC (R22) HFC (R134a, R404A, R407C, R410A, R507) HFO (R1234ze) HFO + HFC (R448A, R449A, R450A, R452A, R513A, R515A, R515B) Connections SAE Flare 1/2"" Kv [m³/h] 1,30 PS [bar] 28 TS [°C] min. -35 TS [°C] max. +90"
RECEIVER VALVES inlet Connecting = 3/4" Male NPT. - outlet Connecting = 3/4" Male SAE. FLARE made from hot pressed brass with Teflon (PTFE) valve seat"
Stop valves by diaphragm Diaphragm Valve 3/4"Flare inlet and outlet . Valve use with the following ASHRAE 34:2019 refrigerants, Class A1: HCFC (R22) HFC (R134a, R404A, R407C, R410A, R507) HFO (R1234ze)HFO + HFC (R448A, R449A, R450A, R452A, R513A, R515A, R515B) Connections SAE Flare3/4" Kv [m³/h] 3,65 PS [bar] 28 TS [°C] min. -35 TS [°C] max. +90"